Fujitsu 10.5kW Ducted Inverter Reverse Cycle Air Conditioner
Fujitsu Indoor ARTG36LHTA Outdoor AOTG36LATL
Ducted air conditioning is surely the ultimate in comfort. The Fujitsu ducted models offer quiet, efficient operation, are easy to maintain, and operated via a wall mounted LCD control.
10.5kW Ducted Inverter Reverse Cycle Air Conditioner
Designed for small roof cavities, the New Fujitsu Ducted Air Conditioning Range is ideal for Brisbane homes which have a scillion roof design. This system can be retrofitted into a new build or easily fitted into an existing Brisbane home if air conditioning is required with easier options than the standard size unit.
You have the comfort of a 5-year warranty on the air conditioning manufacturer, Fujitsu Air Conditioning, and a 5-year warranty on the Advantage Air Zone Control systems in Brisbane. Aussie Air Conditioning Brisbane supplies the most comprehensive air conditioning systems and zone controls. These include Advantage Air Brisbane, Zone 10e and MyAir 5 Zone Control.
With air conditioning there can be huge temperature discrepancies between rooms, depending on their orientation to the sun and whether they are upstairs or downstairs. With MyAir 5, you can manually send more air to hotter rooms. If you prefer everything to be adjusted automatically, you have the option of upgrading to Independent Temperature Control (ITC). Each ITC sensor is like a thermostat, giving you individual room temperature control. They instruct the system to continually adjust the airflow to maintain your selected temperature. As ITC sensors ensure you won't be over air-conditioning rooms, they have the added bonus of saving energy. Sensors can be installed in as many rooms as you like, either at the time of installation or later on.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Filter sign
Indicates the filter cleaning period by lamp.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.
Connectable Distributing Duct
Conditioned air can be distributed to adjacent areas by means of a distribution duct.
Connectable Fresh Air Duct
Allows introduction of fresh air to occupied space.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only
Weekly Timer
Different on-off times can be set for up to 7 days.
You have the comfort of a 5-year warranty on the air conditioning manufacturer, Fujitsu Air Conditioning, and a 5-year warranty on the Advantage Air Zone Control systems in Brisbane. Aussie Air Conditioning Brisbane supplies the most comprehensive air conditioning systems and zone controls. These include Advantage Air Brisbane, Zone 10e and MyAir 5 Zone Control.
With air conditioning there can be huge temperature discrepancies between rooms, depending on their orientation to the sun and whether they are upstairs or downstairs. With MyAir 5, you can manually send more air to hotter rooms. If you prefer everything to be adjusted automatically, you have the option of upgrading to Independent Temperature Control (ITC). Each ITC sensor is like a thermostat, giving you individual room temperature control. They instruct the system to continually adjust the airflow to maintain your selected temperature. As ITC sensors ensure you won't be over air-conditioning rooms, they have the added bonus of saving energy. Sensors can be installed in as many rooms as you like, either at the time of installation or later on.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Filter sign
Indicates the filter cleaning period by lamp.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.
Connectable Distributing Duct
Conditioned air can be distributed to adjacent areas by means of a distribution duct.
Connectable Fresh Air Duct
Allows introduction of fresh air to occupied space.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only
Weekly Timer
Different on-off times can be set for up to 7 days.
Specification
- Model No. - Indoor
- ARTG36LHTA
- Model No. - Outdoor
- AOTG36LATL
- Reverse Cycle System
- Yes
- Cooling Capacity (Watts)
- 10,500
- Cooling Capacity (BTU/h)
- 35,800
- Range (Watts)
- 5,000 - 11,400
- Range (BTU/h)
- 17,100 - 38,900
- Heating Capacity (Watts)
- 12,100
- Heating Capacity (BTU/h)
- 41,300
- Range (Watts)
- 5,100 - 14,000
- Range (BTU/h)
- 17,400 - 47,800
- Power Supply (Volts)
- 240
- Phase-Frequency (Ph - Hz)
- 1-50
- Power Supply Attachment
- Outdoor
- Running Current, Cooling (Amps)
- 13.4
- Running Current, Range (Amps)
- Max: 19.5
- Input, Cooling (Watts)
- 3,180
- Input, Range (Watts)
- Max: 4,670
- Running Current, Heating (Amps)
- 13.9
- Running Current, Range (Amps)
- Max: 20.1
- Input, Heating (Watts)
- 3,300
- Input, Range (Watts)
- Max: 4,800
- Moisture Removal (l/hr)
- 1.5
- E.E.R. - Cooling
- 3.30
- C.O.P. - Heating
- 3.67
- Fan Speed
- 3
- Air Circulation, High (l/s)
- 700
- Compressor Type
- DC Rotary
- Dimensions - Inside Unit (HxWxD Mm)
- 400 x 1,050 x 500
- Weight - Inside Unit (kg)
- 39
- Dimensions - Outside Unit (HxWxD Mm)
- 1,290 x 900 x 330
- Weight - Outside Unit (kg)
- 86
- I.U. Sound Pressure Level (dBA@1mtr)
- 41
- O.U. Sound Pressure Level (dBA@1mtr)
- 52
- O.U. Sound Power Level (dBA)
- 68
- Refrigerant Type
- R410A
- Connection Pipe Sizes, Gas (mm)
- 15.88
- Connection Pipe Sizes, Liquid (mm)
- 9.52
- Pre Charged Length (Metre)
- 20
- Minimum Pipe Length (Metre)
- 5
- Maximum Pipe Length (Metre)
- 50
- Maximum Pipe Height (Metre)
- 30
- Pipe Connection Methods
- Flare
- Outdoor Operating Temp, Cooling Degrees C
- -5 to 46
- Outdoor Operating Temp, Heating Degrees C
- -15 to 24