Fujitsu 3.5kW Multi Head Cassette Air Conditioner AUTG12LVLA
Indoor Unit AUTG12LVLA with Outdoor Unit AOTG24LAT3
Incorporating the latest fan technology, these units fit neatly into the ceiling and distribute conditioned air through 3 or 4 sides of the unit.
3.5kW Multi Head Cassette Air Conditioner AUTG12LVLA
One outdoor unit can be connected to a wide variety of indoor units, including wall mounted, consoles, cassette and ducted units. Each room can be individually controlled, allowing you to set different temperatures in each room, helping save running costs by heating or cooling rooms as required.
Up/Down Swing Louvre
The up/down louvre automatically swings up and down.
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Filter sign
Indicates the filter cleaning period by lamp.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Up/Down Swing Louvre
The up/down louvre automatically swings up and down.
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Filter sign
Indicates the filter cleaning period by lamp.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Specification
- Model No. - Indoor
- AUTG12LVLA
- Model No. - Outdoor
- AOTG24LAT3
- Reverse Cycle System
- Yes
- Capacity Class
- 3.5
- Cooling Capacity (Watts)
- 3,500
- Cooling Capacity (BTU/h)
- 11,953
- Range (Watts)
- 3,700
- Range (BTU/h)
- 12,636
- Heating Capacity (Watts)
- 3,800
- Heating Capacity (BTU/h)
- 12,977
- Range (Watts)
- 4,800
- Range (BTU/h)
- 16,392
- Power Supply (Volts)
- 240
- Phase-Frequency (Ph - Hz)
- 1-50
- Power Supply Attachment
- Outdoor
- Running Current, Cooling (Amps)
- 0.19
- Input (Watts)
- 23
- Fan Speed
- 4
- Air Circulation, High (l/s)
- 169
- Compressor Type
- DC Twin Rotary
- Dimensions - Inside Unit (HxWxD Mm)
- 245(49)x570(700)x570(700)
- Weight - Inside Unit (kg)
- 15(2.6)
- Dimensions - Outside Unit (HxWxD Mm)
- 700x900x330
- Weight - Outside Unit (kg)
- 55
- I.U. Sound Pressure Level (dBA@1mtr)
- 37
- O.U. Sound Pressure Level (dBA@1mtr)
- 48
- O.U. Sound Power Level (dBA)
- 64
- Refrigerant Type
- R410A
- Connection Pipe Sizes, Gas (mm)
- 9.52
- Connection Pipe Sizes, Liquid (mm)
- 6.35
- Minimum Pipe Length (Metre)
- 5
- Maximum Pipe Length (Metre)
- 25
- Maximum Pipe Height (Metre)
- 10
- Pipe Connection Methods
- Flare
- Outdoor Operating Temp, Cooling Degrees C
- -10 to 46
- Outdoor Operating Temp, Heating Degrees C
- -15 to 24